• Sonics ultrasonic processors
  • VC750
  • Power 750W, standard amplitude rod processing volume from 50ml to 500ml.
  • VC750
  • Sonics ultrasonic processors
  • Power 750W, standard amplitude rod processing volume from 50ml to 500ml.
Sonics ultrasonic processors VC750 is capable of safely processing various organic and inorganic materials ranging from 250 microliters up to 1 liter*. Typical applications include nanotechnology (production of nanoparticle materials and graphene dispersions), cell lysis, sample preparation, homogenization, ChIP assay, emulsification, dispersion, and degassing, as well as applications in the field of sonochemistry liquid processing.
Product Introduction
Sonics ultrasonic processors VC750 is capable of safely processing various organic and inorganic materials ranging from 250 microliters up to 1 liter*. Typical applications include nanotechnology (production of nanoparticle materials and graphene dispersions), cell lysis, sample preparation, homogenization, ChIP assay, emulsification, dispersion, and degassing, as well as applications in the field of sonochemistry liquid processing.


Product Features
◆Energy monitor
◆Digital power meter
◆Integrated temperature controller to prevent overheating of samples, monitoring and controlling sample processing temperature in the range of 1℃ to 100℃
◆Based on microprocessor and programmable technology
◆10-hour process timer
◆Independent on/off pulse generator
◆Variable power output control


Experiment Objectives
1. Understand the basic principles of ultrasonic cell disruption
2. Master the basic techniques of ultrasonic cell disruption


Experimental Principle
When strong sound waves act on a solution, the cavitation phenomenon of bubble generation, growth, and fragmentation is related to the cell lysis. The shock wave and shear force caused by the cavitation phenomenon cause the cells to break.
Materials and Reagents
10ml bacteria, beaker, crushed ice, 75% alcohol cotton ball.


Probe Selection  
Probe Model and Size Capacity for Cell Disruption
2mm 150ul-5ml
3mm 250ul-10ml
6mm 10ml-50ml
10mm 10ml-250ml
13mm 50ml-500ml


Technical Parameters  
Model: VC 750
Frequency: 20KHz
Power: 750W
Standard amplitude bar: Φ13mm
Standard amplitude bar length: 136mm
Amplitude bar overall size: 235 x 190 x 340 mm
Amplitude bar material: Titanium alloy Ti-6Al-4V
Standard amplitude bar processing capacity: 50ml to 250ml
Optional amplitude bars: Φ2mm, Φ3mm, Φ6mm, Φ10mm
Amplitude bar weight: 900g
Crushing capacity: 50-500ml
Duty cycle: 1-99%
Power adjustment range: Continuously adjustable (20-750w)
Interval time: 0.1-99.9s
Temperature protection setting: /
Power amplitude display: Yes
Working frequency range: Energy monitor digital wattmeter, automatic tuning and automatic amplitude compensation
Working time: Microprocessor-based - programmable 10-hour timer 1-59 second independent/on/off pulse
Ultrasonic time: From 1 second to 10 hours
Working mode: Interval/continuous
Power supply: 220/110V 50Hz/60Hz or 117V, 50/60Hz unless otherwise specified
Net weight: 6.8kg
Main unit + transducer weight: 3680g
Product List
VC750 Unit
Host Machine Unit
Toolbox set
Power cord piece
Soundproof box set
Special Crushing Cup Piece
User manual copy
Description
1
1
1
Optional
Optional
1